Racking Engineering and Compliance Services
Convex Services provides engineering and compliance services for warehouse racking in Quebec and Ontario:
racking inspections that document damage and engineering conformance,
engineering certification that delivers a stamped capacity report and printed capacity placards, and
seismic and loading analysis that tells you how your existing racking will perform before you move it, modify it, or buy more.
Every one of these services is backed by clear documentation; a report, a stamped certification, or an engineer's assessment.
Our Racking Engineering and Compliance Services
| Who is this for? | What do I receive? | |
|---|---|---|
| Racking Inspection | Facilities that need to know their current condition and conformance status | A full inspection reports anomalies, severity classification, and engineering conformance gaps |
| Engineering Certification | New racking, used racking, or existing racking that needs a defensible, posted capacity | A stamped capacity report, engineer-sealed certification, and printed capacity placards installed throughout the facility |
| Seismic & Loading Analysis | Anyone planning a move, a reconfiguration, or a used-rack purchase | An engineer's assessment of how capacities change under site-specific seismic and loading requirements |
Learn more about each Engineering & Compliance service by clicking on the down-downs below.
Racking Inspection
What a Convex Services racking inspection covers
Schedule our team and we walk your facility section by section, aisle by aisle. We review two things at once:
- Damage. Bent or buckled uprights, dented or unseated beams, missing or damaged safety clips and pins, cracked or lifted baseplates, loose or missing anchors, compromised braces and diagonals, out-of-plumb frames, and impact damage at forklift height. Findings are classified by severity so you can appropriately plan for repairs.
- Engineering conformance. Whether the system as it stands today matches how it was designed and certified to be used. That covers beam level configuration versus the original design, first beam level heights, anchoring, missing components, unauthorized modifications, row spacers and flue spaces, load orientation, and whether posted capacities (if any exist) still reflect reality.
Our inspection approach follows the damage identification, classification, and corrective action framework in applicable CNESST and provincial OHS obligations.
What you get: the report
You receive a full written inspection report. It gives you a clear picture of what work is required to bring the warehouse into compliance with the regulations that apply to your site, location by location, with severity ratings and prioritized corrective actions.
The report is yours, empowering you to make your own decisions. Most clients ask us to do the corrective work because it is efficient and are familiar with the site.
When to book an inspection
- You have never had a formal rack inspection, or it has been more than 12 months
- A forklift hit a frame and you are not sure whether it is still safe to load
- You are taking over a building with racking already installed
- Your insurer, a customer audit, or a CNESST visit has asked for documentation
- You inherited racking with no capacity signage and no drawings
Engineering Certification
Certification for new or existing pallet racking
Whether the racking is brand new, second-hand, or has been standing in your building for twenty years, we can put engineering behind it. Our team documents the system as configured, frame and beam profiles, gauges, connections, bracing, anchoring, beam levels, and the floor slab it sits on, and a professional engineer analyzes it against the loads it actually has to carry.
That analysis is performed in accordance with all applicable local seismic calculations, using the site-specific hazard values for your building's coordinates and site designation under the current code, plus the design provisions of CSA S345 and the user requirements of CSA A344. Dead load, live load, impact, and seismic demand are all in the calculation, not just what the pallets weigh.
What you get: report, stamp, and placards
- A comprehensive capacity report. Configuration-specific capacities: per beam level, per bay, per frame, along with the assumptions the capacities depend on. This is the document that answers "how much can we actually put here?"
- Engineer-stamped certification. A sealed, signed certification from a licensed professional engineer. This is what you hand to a CNESST inspector, an insurance underwriter, a corporate EHS auditor, or a customer running a supplier audit. An email from a supplier saying the rack "should be fine" is not this.
- Printed capacity placards, installed. We print and install load capacity placards throughout the warehouse, positioned so they are legible from the aisle where the load is placed. Placards put the key information from an engineering report directly where it matters, giving operators clear load information they can reference on the warehouse floor.
Seismic and Loading Analysis
Engineering analysis on existing racking, before you move it
This service exists for one reason: decisions made before a move can maximize value, and decisions made after a move are expensive.
If you are relocating racking to a new building, reconfiguring a facility, adding beam levels, changing pallet weights, or buying used racking from another site, the capacities you have been relying on may no longer be relevant. Seismic demand is tied to the coordinates and soil conditions of the new site. Racking that carried 3,000 lb per level in the old building might not carry it in the new one; same steel, different ground.
Loading changes have the same effect. Heavier pallets, larger beam spacing, a shift from selective to double-deep, new regulations, a new lift truck class, etc. Each one changes the demand on the structure.
What we analyze
- Site-specific seismic hazard values for the destination site
- Existing frame and beam capacities as configured, and as you intend to reconfigure them
- Anchoring and slab conditions at the new location
- Proposed beam elevations, pallet weights and new type of equipment
- What changes, and by how much versus your current setup
What you get: an engineer's assessment you can make decisions with.
You receive a professional engineer's assessment that tells you, before you finalize anything:
- Whether the existing racking works as-is at the new site or under the new weight rating
- What the revised capacities would be
- What modifications would be required to hit your target capacity: additional bracing, heavier frames, larger footplates, reduced beam levels
- Whether the used racking you are about to buy is worth buying
Why Racking Compliance Matters Right Now
Pallet racking is a working structure. It carries live load, absorbs forklift impact, gets reconfigured by someone without authorization, and is expected to stand up in a seismic event, which can often be decades after anyone last looked at the original engineering.
Two things have changed the compliance picture for Canadian warehouse operators:
- Seismic requirements were reworked. The National Building Code of Canada 2020, adopted into Quebec's Construction Code, Chapter I – Building, by the Régie du bâtiment du Québec and reflected in provincial codes elsewhere, moved to Canada's 6th Generation Seismic Hazard Model. Site effects are no longer handled with lookup tables of Fa/Fv coefficients. Hazard values are now calculated site by site, based on your location's shear wave velocity (Vs30) or site class. Two buildings a few kilometres apart can carry different seismic demand. Design values in the Montréal region shifted meaningfully under the new model.
- Rack design standards were updated. CSA A344:24, User guide for steel storage racks, is now in its second edition and points to CSA S345 for rack design and construction, replacing the former CSA S16 Annex N. CSA A344 is also the document regulators and inspectors reach for on damage classification, corrective action, and modifications to existing racking systems.
The practical consequence: racking that was engineered under an older code, or never engineered at all, may not have a defensible capacity today. And a CNESST inspector in Quebec, or an inspector under Ontario's
Occupational Health and Safety Act, is going to ask for documentation, not opinions.
Standards and Regulations We Work To
- CSA A344:24 — User guide for steel storage racks (2nd edition; damage assessment, corrective action, modifications, capacity documentation)
- CSA S345 — design and construction of steel storage racks (replaced CSA S16, Annex N)
- CSA S16 — design of steel structures
- CSA B335 — safety standard for lift trucks
- National Building Code of Canada 2020 — including the 6th Generation Seismic Hazard Model and site-specific seismic hazard values
- Quebec Construction Code, Chapter I – Building (NBC 2020, amended) — as administered by the Régie du bâtiment du Québec
- CNESST requirements in Quebec, and the Occupational Health and Safety Act and its regulations in Ontario
Why Warehouse Operators Choose Convex Services
Engineering-first, not sales-first.
The inspection report is the product. You are not buying a pretext for a quote.
We do the work too.
If the report identifies corrective work, we can install or dismantle and move — with the same team that already knows your building.
Fully certified crews.
100% certified for forklift operation and working at height, including skyjacks and scissor lifts.
Live-warehouse experience.
Including food-grade facilities, cold storage, and freezer environments, where inspection and remediation have to happen without shutting you down.
Bilingual, and local.
Based in Dorval, serving Greater Montreal, Quebec, and Ontario.
Licensed professional engineering.
Stamped certifications, not vendor letters.
Service Area
Convex Services delivers racking inspections, engineering certification, and seismic analysis throughout Quebec, Ontario and other parts of canada. Some of the cities that we frequently service in the Greater Montreal Area include;
- Vaudreuil-Dorion
- Saint-Laurent
- Anjou
- St Eustache
- Baie-D'Urfe
- Lachine
- Montréal-Est
- Mirabel
- Pointe-Claire
- Lasalle
- Boucherville
- Blainville
- Dorval
- Laval
- Longueuil
- Terrebonne
Frequently Asked Questions
How often should pallet racking be inspected?
Industry practice, consistent with the guidance in CSA A344, is a documented inspection by a qualified party at least annually, supported by regular internal visual checks by trained staff and an immediate inspection after any significant impact. Facilities with heavy lift truck traffic, seasonal peaks, or frequent reconfiguration often inspect more often.
Do I have to do the repairs you recommend, with you?
No. The inspection report is a standalone deliverable and it is yours. You can act on it with any contractor, or use it for internal planning, insurance, or audit purposes.
What is a rack capacity placard, and is it required?
A capacity placard is posted signage stating the certified load capacity of the racking as configured. Posted capacity information is a core expectation of CSA A344 and of occupational health and safety inspectors in both Quebec and Ontario. It is how the engineering reaches the people actually loading the rack. Convex prints and installs placards as part of engineering certification.
Can you certify used or existing racking?
Yes. Both new and existing pallet racking can be engineered and certified. For used racking, we strongly recommend the seismic and loading analysis before purchase, so you know whether it will meet your target capacity at your site.
Why did my racking capacity change when I moved buildings?
Because seismic demand is site-specific under NBC 2020. Hazard values are now derived from your building's location and shear wave velocity (Vs30) rather than broad site-class coefficients, so the same racking can be certified for different capacities in different buildings.
Do you work in food-grade and cold storage facilities?
Yes. Our team is qualified for inspection, certification, and remediation work in food-grade facilities, refrigerated warehouses, and freezer environments, including the specialized gear and hygiene protocols those sites require.
Are your certifications valid for CNESST?
Our certifications are prepared and sealed by a licensed professional engineer in accordance with applicable Quebec regulations and the current Construction Code, and are intended to serve as the documentation CNESST inspectors ask for. We also serve Ontario facilities under the applicable OHSA requirements.
How long does an inspection take?
It depends on facility size, rack density, and access. Most single-building inspections are completed in one visit, with the report delivered afterward. Contact us with your square footage and section count for a timeline.
Get Your Racking Compliance Picture in Writing
You cannot fix what you have not measured, and you cannot defend what you have not documented. Start with an inspection, get certified with stamped capacities and installed placards, or find out what your racking is worth structurally before you move it.
Whichever one you need, you walk away with a document — and a clear decision.